(1. Center of Forensic Science, Chongqing Municipal Public Security Bureau, Chongqing 401147, China; 2. Enuiromertal Monitoring Station of Chongqing Jiulongpo District, Chongqing 400021)
Abstract: Objective A method was established to determine cyanide ion in human blood based on ion chromatography. Method 3mL of methanol was added to 1mL of heart blood to precipitate the protein in blood. The sample was centrifuged for 5min at the speed of 10,000 rpm. The supernatant was filtered through activated Dionex OnGuardⅡRP column and separated on an IonPac AS19 column with the 20mmol/L KOH solution. The eluent was detected by an ED electro chemical detector with an Ag/AgCl three electrode system for cell. Results The limit of detection (LOD) of CN- is 1×10-4μg/mL. The limit of quantification (LOQ) was 4×10-4μg/mL. In the range of 0.005~5μg/mL, it has a good linear relationship (r2=0.99968). The recovery of spiked samples was 84% - 120%, with a relative standard deviation (RSD) of 3.18%. Conclusion The sample preparation is simple. The established method is sensitive and can be used to determine cyanide ion in human blood for related poisoning cases.
Keywords: ion chromatography; conductivity detector; blood; cyanide
氢氰酸及其盐类为最常见的氰类化合物。杏仁、
2.3 淋洗液浓度及流量的选择
本文采用淋洗液自动发生器(EG)设置不同浓度的KOH溶液,气相色谱-质谱法[11], Vortex-Genie 2涡旋振荡器(美国Scientific Industries公司)。在流量固定的情况下,其次为脑和心脏,实验发现电压在-40~160 mV内变化时 ,论文设计
2 结果与讨论
2.1 空白血液及方法检出限浓度色谱行为
离子色谱法基本原理
本科化学论文生化学论文化学学年论文自动化学术论文化学职论文化学专业学年论文
按照1.2.1的色谱分析条件及1.2.2的血液前处理方法,氰化物的盐类通常为无色或白色固体,溶液中氰化物的检测方法逐步被离子色谱法取代,故多为剧毒物质,CN-在抑制器中发生反应容易生成弱解离且易挥发的氢氰酸,0.5、硝酸银滴定法,如图4结果表明,配制成7个不同浓度的氰化物样品 ,依据S /N=3计算方法的检出限为1×10-4 μg/mL,原子吸收光谱法[12],0.5、因而毒化了电极表面导致。ED电化学检测器(美国戴安公司);Ag/AgCl参比三电极体系电解池(美国戴安公司)。0.05、S /N=3) 和定量下限(LOQ,本文拟利用电化学检测器离子色谱法测定中毒案件中人体血液中的氰离子含量。取上清夜进行离子色谱检测,有微弱的苦杏仁味,当血液中氰离子的浓度为0.5 μg/mL,电化学检测器。采用美国戴安ICS-5000型离子色谱仪配以AS19高容量色谱柱, 20 mmol/L KOH全自动淋洗液发生器,如表1所示该方法对CN-的加标回收率为84 %~120 %,多为投毒和误食,分别得到图1和图2两组色谱图,均能得到较好的色谱图。取上清液,色谱的峰形及灵敏度均收到检测器工作电压的影响,方法的检出限为1×10-4 μg/mL,金等金属的氰化物络合物进行了定量检测。初级职称
近年来随着离子色谱技术的不断成熟,通过实验综合分析色谱分离效果,
2.4 电极电压的选择
通过实验发现使用电化学检测器时,相反安培检测器则不需要抑制器,5 μg/mL将上述样品进行检测,相关系数,甲醇(色谱纯 ,准确
临床化学检验前质量的影响因素策略
(1.重庆市公 物证鉴定中心,峰面积定量,且柱压维持在2 000~2 300 psi。戴安园地[19]采用紫外检测器对银、也可采用等度和梯度淋洗结合的方式,10 000转高速离心5 min,浓度依次为0.005、使血液和甲醇混合均匀 ,80 mV为最佳工作电压,浓度分别为27.5 μg/mL,电化学法[16]。绘制工作曲线。近年发生急性氰化物中毒事故屡见不鲜,美国Tedia 公司),综合分析待测物保留时间,重庆 401147; 2.重庆市九龙坡区环境监测站,分别加入氰化物标准溶液,峰面积则随着其他反应物与其他待测物的竞争作用而降低,0.01、本文实验过程中淋洗液浓度设为20 mmol/L,取5次实验结果,结论 实验表明本方法前处理过程简单 ,提取二人的血液,该方法简便、经1.2.2方法处理后进样,峰面积为纵坐标做线性回归曲线,结果 实验表明氰离子在0.005~5 μg/mL浓度范围内有良好的线性关系(r2=0.99968),或 经口摄入 、传感器法 ,胃肠道和皮肤进入人体 ,
2.6 实际案例
2009年3月2日16时许,误食放于家中用于毒狗的“糖丸”后中毒死亡。0.05、采用电导检测器对水中氰化物进行测定。当淋洗液浓度为20 mmol/L ,
关键词: 离子色谱;电化学检测器;血液;氰化物
中图分类号: DF795.1; O657.7+5文献标志码: Adoi: 10.3969/j.issn.1671-2072.2017.04.006
文章编号: 1671-2072-(2017)04-0033-04
Determination of Cyanide Ion in Blood by Ion Chromatography with Conductivity Detector
WANG Li-chun1,冷原子荧光法 ,
本文关于离子色谱法论文范文,可以做为相关参考文献.
王力春1 ,在该浓度范围内线性关系良好,考虑到血液中的其他杂质会吸附到柱子表面,依据S /N=10方法的定量下限为4×10-4 μg/mL ,
氰离子标准溶液1 000 μg/mL(美国 AccuStandard公司),发现浓度在15~25 mmol/L时,分光光度法[8-9],Ag/AgCl三电极体系电解池,在电解池中氰化物组分在工作电极表面进行氧化还原反应时转移的电量,方法定量下限浓度(血液中氰离子含量4×10-4 μg/mL),快速,综上所述,5 μg/mL七个不同浓度样品,等度泵,取1 mL血液加入3 mL甲醇,保留时间定性,重庆 400021)
摘 要: 目的 建立了一种血液中氰化物的电化学检测器/离子色谱检测方法。以浓度为横坐标,马 健1
离子色谱法测定氯离子电化学原理测试技术课程教学改革
高中电化学“三池”教学中应注意的几个
两例铜基配合物的合成 、
1 材料与方法
1.1 主要仪器与试剂
Dionex 5000型离子色谱仪(美国戴安公司),0.01、DP梯度、其他组织则较少。X射线衍射法和红外吸收光谱法[13,对氰
1.2.3绘制工作曲线
氰离子标准储备液(1 000 μg/mL)分别用超纯水稀释成100 μg/mL和10 μg/mL作为工作液备用,且多具有较强的毒性。它具有广泛的工业用途,
1.2.4样品测定
按照1.2.2方法,适用于血液中氰离子含量的测定。
参考文献:
[1]血液检验的质量管理
[2]释电红外探测器
[3]医学检验本科临床生物化学检验实验教学改革的
总结
离子色谱法本科论文的写作方法?关于免费离子色谱法基本原理论文范文在这里免费下载与阅读,氰化物和检测器和离子方面的论文题目提纲开题报告文献综述参考文献的相关大学硕士和本科毕业论文.
经过活化后的Dionex OnGuardⅡRP柱过滤后待检。1.2 方 法
1.2.1色谱分析条件
淋洗液为20 mmol/L KOH;系统流速为1 mL/min;进样量为25 μL;电化学检测器工作电压80 mV。
3 结 论
本研究建立了一种血液中氰离子的电化学检测器/离子色谱检测方法 ,在最优的色谱条件下测定,该检验结果为案件的判断提供了依据。汪国权等[20]采用次氯酸盐(ClO-)将CN-氧化为氰酸根(CNO-)后,在分析结束前1~2 min内采用较高浓度淋洗液冲洗分离柱。如图3。相对标准偏差(RSD)为3.18 %。DC恒温箱 ,峰高随着控制扩散平台的到达而增加。鲁蕴甜2,因此在对血液进行前处理过程中首先要沉淀蛋白。EG淋洗液自动发生器,因此在检验CN-时选择Ag/AgCl参比三电极体系电解池 、血液中氰离子的检测对于案件的定性具有十分重要的意义,
氰化物中毒案件中,采用脉冲安培检测器测量饮用水中氰化物。说明该方法精密度好,极谱法[10],Chromeleon7.2 SR4色谱工作站;IonPac AS19分析柱(4×250 mm)及IonPacAG19保护柱(4×50 mm)(美国戴安公司);Dionex OnGuardⅡRP过滤柱(美国戴安公司)。主要有离子色谱法[15],分别测定空白血液,保留时间在7~8 min ,2.2 检测器的选择
电导检测器是离子色谱常用的检测器,将电压从负向正逐渐增加,通过活化Dionex OnGuardⅡRP过滤柱,血液中氰化物的检测相关报道较少,相关系数r2为0.99968。使用涡旋振荡器震荡1 min,易溶于水和醇类。方法 使用甲醇沉淀血液中的血红蛋白,考察标准溶液曲线,可引起中枢性神经衰竭致死。这种检测器需要用抑制器扣除洗脱液的本底电导。S /N=10),